High-Quality Speciality Electronic Water Descaler Machine

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $480-8,000/ Piece
Port: Shanghai, China
Production Capacity: 5000PCS/Year
Payment Terms: L/C, T/T, D/P, Western Union, Paypal
Usage: Environmental Protection, Chemical Industry
Motive Force: Electric power
Style: Vertical
Certification: SGS, ISO
Input Power: 220V, 50Hz
Scale Resist: More Than 95percent

You Might Also Like


Basic Info

Model NO.: CLDC
Bacterial Killing: More Than 95percent
Algae Removing: More Than 95percent
Trademark: peide
Transport Package: Wooden Cases
Specification: ISO 9001
Origin: China

Product Description

High-quality Speciality Electronic Water Descaler Machine


The electric descaler widely used in central air conditioning system, industry chilling system, heat exchange system, boiler system, etc.
Product structure 

It consists of main and vice part, which can be installed together or separated. Main part is a high-frequency signal generator, vice part can transfer signal to water.
Working principle

1.scale resist and prevent
Based on Electromagnetic Theory, invented by Dr. Lorentz, the electric water descaler stops calcium carbonate and magnesium carbonate formation. Water absorbs electromagnetic energy, which physical structure changes and chain water molecules break into smaller single water molecule. The single water molecule covers negative and positive ion of dissolve saline, which reduces electrostatic attraction and effective collision, but increase water dipole moment and compatibility to negative and positive saline, which finally loose pipe wall scale and to remove them.

2.kill bacterial and algae 
The electromagnetic wave creates turbulence flow, which destroys cell wall's ion channel and changes cell's living ambient. Cells die as of no suitable living area. What's more, large amount of single water molecules covers dissolve oxygen, which cut microorganism oxygen demanding so that to prevent microorganism sediment formation.

3. rust resist and corrosion prevention
Oxygen molecule in water become inert oxygen as covered by singe water molecule, which cut off oxygen-demanding for mental rust. 
The electromagnetic field create "Skin-effect", which gathers negative charge inside pipeline wall. Water molecule covers positive charge, it rejects Fe ion dissolve from metal pipe. Negative charge on pipeline wall attract positive Fe ion to form Fe3O4 membrane.
1.Make use of high-frequency electromagnetic technology in water treating, which can increase at least 30% work efficiency.
2.The technology can treat max water hardness of 700mg/L. ( in CaCO3)
3.The special alloy material can make use life time to 20years. 
4.Signal light shows electrode energy release enough or not. 
5.Extra add drain outlet, which is easy to drain scales.
Technical parameter 

1.Input power: 220V, 50HZ
2.Water hardness require: ≤700mg/L(CaCO3)
   Temperature: ≤95ºC
   Work pressure: 1.0MPa,1.6MPa
   Flow speed: ≤2.8m/s
3. Scale resist: ≥95%
    Bacterial killing: ≥95%
    Algae removing: ≥95%
    Reduce corrosion: reduce to 1/10 of origin
4. Function time: within 2 hours in after treating. Half-time is 1 hour. 

ItemMade by PEIDEMade by others companyInstruction


Shielding mesh

Shielding mesh makes sure electrodes work separately, without any interruption 

No shied mesh

Increase efficiency 30%
2Electrode materialAlloy materialBrassLife time 5-7times than brass
3Circuit board and electrode connection way 
Makes use of shielding connection, it can transfer energy to electrodes fully

Connect directly, which will cause dis-connect after long using. No shielding design, which has interruption to other equipment.

Peide reduce the energy consumption to the lowest
4In/outlet designAdd extra guide plateNoPeide design can transfer more stable electromagnetic energy
5Transformer materialTransformer works well even in severe ambient, (even in water) electric elements all importedLess ability in high temperature and high humidity ambient.Peide design can install indoor or outdoor
6Protection setting on main partThe special temperature design can ensure main part work less than 40ºC.Over 50ºCMain part life time increases 3-5times.
7Drain designYesNoPeide design more completed.
8Vice part inside treating With phosphorization treatingNoIncrease strength of magnetic field.

Model options

Pipe diameterABCD

Water Flow


1.Water equipment should be installed before equipment that need protect. It will be better to close to pump. All recycling water should flow into water treatment equipment fist.
2.If there's no big default and scales on old system, water treatment equipment can be installed directly, or else, users should clean pipes' scale first. 
3.In central air-condition, before stop equipment working , users can add inhibitor help reduce corrosion on the equipment. 
4.Rain proof and dirt proof device will be used, if the equipment is installed outside. 
5. If pipe line is too long, users should make sure that there's a water treatment equipment at a distance, so that the function will be much more better.
6. There should be a 300mm free space room for easy to repair. Make sure to inspect if there's leak problem on the connections when equipment is finished installation.
7. When installed, the direction of flow rate should be the same as equipment. No reverse. Also drain valve and pipe need to installed at the drain.
8. Users not allowed to open the main frame. We will not in the charge of people death or hurt by high pressure Electricity.
How to use
-Red indicator light is the power indicator light.
-Green light is working indicator light.
-Red and green light is light on, it means equipment work Well.
How to deal with breakdown
Normally inspect according to the situation of red and green indicator light.
1)Red indicator light is the power indicator light. Green light is working indicator light.
2)Red light works, green light not work, users should stop the equipment, and notice the factory or technicians to repair.
3)Green light works, red light not work, it shows equipment in normal operation, users can notice the factory to repair at the same time.

                                     Welcome To Inquire, We Will Offer You The Best Items !

Send your message to this supplier

avatar Ms. Yang

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now