Home
Product Directory
Industrial Equipment & Components
Environment Protection Device
Sewage Treatment Equipment
Cooling Towers Water Treatment Strong Magnetic Water Treatment Equipment
US$470.00 - 500.00 | 1 Piece (MOQ) |
Production Capacity:
2, 000PCS/Year
Transport Package:
Wooden Packaging
Payment Terms:
L/C, T/T, D/P, Money Gram, Western Union
Peide Water Treatment Equipment Co., Ltd.
Jiangsu, China
Last Login Date:
Sep 30, 2025
Main Products:
UV Sterilizers, Electronic Water Descaler, Condenser Tube Cleaning System, Ion Bar, Chemical Dosing System, Bag Filter Housing, Self Cleaning Filter, Multi-Cartridge Filter Housing, Sand Filter, Cooling Tower Descaler
Find Similar Products
Product Description
Company Info
Basic Info.
Model NO.
CLDQ-DN
Method
Physical Treatment
Usage
Industrial, Agriculture, Hospital, Water Descaler
Water Treatment Capacity
25-8000t/H
Magnetism Intensity
6000gauss
Diameter(Mm)
10-125mm
Material
Carbon Steel
Prevent Scale Rate
More Than 90%
Germicidal Rate
More Than 95%
Kill Algae Rate
More Than 95%
Application
Descaling Equipment
Cetificates
ISO,SGS
Condition
New
Trademark
PEIDE
Specification
ISO9001: 2008
Origin
China
HS Code
8421299090
Product Description
Cooling Towers Water Treatment Strong Magnetic Water Treatment Equipment
1. Feature of water treatment equipment
1. Remove and prevent pipe scale and rust formation
2. Don't need to maintenance personnel management, maintenance cost low
3. Technology is to achieve zero emissions, save a lot of water.
4. Improve the system in the thermal efficiency, save energy(15%---30%)
5. Do not use chemicals, Environmental Pollution free.
6. Don't consume energy and long service life.
7. Small volume, convenient installation.
8. The descaling process can produce hydrogen peroxide, reduce the water content of bacteria
2. Scope of application
1. Industrial circulating cooling water system, DC straight row of cooling water system, industrial process water system.
2. Boiler system(smoke pipe, water pipes, hot water), fue system
3. Heat exchanger.
4. Central air conditioning, cold water machine, cooling water, cooling towers, pipes.
5. Air compressor cooler, plastic molding machine, dehumidifier, industrial washing machine.
6. Oil pipe, water pipe, water plant...
3. Working principle of this magnetic water treatment equipment
Inhibit scale
Negative charge of bicarbonate ions (HCO3-) can not absorb on the surface of pipe on the function of repulsion from the negative charge pipe. Carbonate crystals will precipitate from water in strong magnetic activation. The stable partial diamond crystal will change. Amorphous crystals can not congregate together forming large polycrystalline but to soft aragonite. Aragonite has no ability of absorbing on the surface of pipe. So it will suspended in the water and precipitate when the water flow is smooth.
Clean scale by the magnetic water treatment
Positive charge hydrogen ion will be absorbed by negative charge pipe and dissolve generated scale and corrosion. Activation of polar water molecules will penetrate into the scale and do the effect of constriction and sorption. Scale will be off from the surface of pipe gradually. The time of clean scale is based on the depth of scale and system working condition.
Inhibit corrosion by the magnetic water treatment
Pipe and water form bipolar nature. Water is positive and pipe is negative. The negative charge of pipe form cathode protection in order to electrochemical corrosion occur. The negative charge oxygen is repelled by negative charge to not corrode the pipe. The bacterial and algae will be killed and can not produce mucus. So there will be no slime to reach to inhibit the occurrence of bio corrosion.
Kill bacterial and algae by the magnetic water treatment
Hydroxyl ions which is generated through ionization reaction has most natural oxide sterilization function. Free activation oxygen can destroy biological macromolecules, microbial membrane peroxidation and damage the dismutase. What's more, magnetic field cause microorganisms, bacterial and other cells passivation, enzyme inactivation. The environment to survival is damaged, the bacterial and algae can not survival. At the same time, the system environment is alkaline which is not conducive to the growth of bacterial and algae.
Welcome to inquire, We will offer you the best item!
1. Feature of water treatment equipment
1. Remove and prevent pipe scale and rust formation
2. Don't need to maintenance personnel management, maintenance cost low
3. Technology is to achieve zero emissions, save a lot of water.
4. Improve the system in the thermal efficiency, save energy(15%---30%)
5. Do not use chemicals, Environmental Pollution free.
6. Don't consume energy and long service life.
7. Small volume, convenient installation.
8. The descaling process can produce hydrogen peroxide, reduce the water content of bacteria
2. Scope of application
1. Industrial circulating cooling water system, DC straight row of cooling water system, industrial process water system.
2. Boiler system(smoke pipe, water pipes, hot water), fue system
3. Heat exchanger.
4. Central air conditioning, cold water machine, cooling water, cooling towers, pipes.
5. Air compressor cooler, plastic molding machine, dehumidifier, industrial washing machine.
6. Oil pipe, water pipe, water plant...
3. Working principle of this magnetic water treatment equipment
Inhibit scale
Negative charge of bicarbonate ions (HCO3-) can not absorb on the surface of pipe on the function of repulsion from the negative charge pipe. Carbonate crystals will precipitate from water in strong magnetic activation. The stable partial diamond crystal will change. Amorphous crystals can not congregate together forming large polycrystalline but to soft aragonite. Aragonite has no ability of absorbing on the surface of pipe. So it will suspended in the water and precipitate when the water flow is smooth.
Clean scale by the magnetic water treatment
Positive charge hydrogen ion will be absorbed by negative charge pipe and dissolve generated scale and corrosion. Activation of polar water molecules will penetrate into the scale and do the effect of constriction and sorption. Scale will be off from the surface of pipe gradually. The time of clean scale is based on the depth of scale and system working condition.
Inhibit corrosion by the magnetic water treatment
Pipe and water form bipolar nature. Water is positive and pipe is negative. The negative charge of pipe form cathode protection in order to electrochemical corrosion occur. The negative charge oxygen is repelled by negative charge to not corrode the pipe. The bacterial and algae will be killed and can not produce mucus. So there will be no slime to reach to inhibit the occurrence of bio corrosion.
Kill bacterial and algae by the magnetic water treatment
Hydroxyl ions which is generated through ionization reaction has most natural oxide sterilization function. Free activation oxygen can destroy biological macromolecules, microbial membrane peroxidation and damage the dismutase. What's more, magnetic field cause microorganisms, bacterial and other cells passivation, enzyme inactivation. The environment to survival is damaged, the bacterial and algae can not survival. At the same time, the system environment is alkaline which is not conducive to the growth of bacterial and algae.
No | Model | Diameter(mm) | Flow(m 3 /H) | Magnetism intensity |
1 | CLDQ-DN10-16 | 10 | 1 | 6000Gauss |
2 | CLDQ-DN15-16 | 15 | 1.8 | 6000Gauss |
3 | CLDQ-DN20-16 | 20 | 3 | 6000Gauss |
4 | CLDQ-DN25-16 | 25 | 4.6 | 6000Gauss |
5 | CLDQ-DN32-16 | 32 | 6 | 6000Gauss |
6 | CLDQ-DN40-16 | 40 | 12 | 6000Gauss |
7 | CLDQ-DN50-16 | 50 | 19 | 6000Gauss |
8 | CLDQ-DN65-16 | 65 | 33 | 6000Gauss |
9 | CLDQ-DN80-16 | 80 | 50 | 6000Gauss |
10 | CLDQ-DN100-16 | 100 | 80 | 6000Gauss |
11 | CLDQ-DN125-16 | 125 | 125 | 6000Gauss |
Welcome to inquire, We will offer you the best item!