消息
×
loading..
x

Commercial Recycle Water Filters System

US$480.00 - 500.00 1 Piece (MOQ)
Production Capacity:
2, 000PCS/Year
Transport Package:
Woodencase
Payment Terms:
L/C, T/T

Last Login Date:

Oct 31, 2025

Main Products:

UV Sterilizers, Electronic Water Descaler, Condenser Tube Cleaning System, Ion Bar, Chemical Dosing System, Bag Filter Housing, Self Cleaning Filter, Multi-Cartridge Filter Housing, Sand Filter, Cooling Tower Descaler

Find Similar Products

Product Description

Company Info

Basic Info.

Model NO.
XLQ
Usage
Environmental Protection, Chemical Industry
Motive Force
Electric power
Performance
Efficient Filtration
Certification
SGS, ISO
Material
Carbon Steel, 304ss or 316L
Unit Capacity
15-900t/H, Achieve Parallel Install to Achieve Big
Micron
20-500um
Control Way
Differential Pressure, Time and Manual
Back Wash Time
60-120s
Clean Way
Scanning Type
Screen
316ss (Woven, ,Multi-Layer Sintered, Wedge)
Drain Valve
Cast Ion with Antir-Corrosion Painting
Application
Water Filter
Install Way
Vertical Installation
Trademark
PEIDE
Specification
ISO9001: 2008
Origin
China
HS Code
8421299090

Product Description

Commercial Recycle Water Filters System 

How It Works

The unit consists of two stages of filtration, a coarse pre-filter and a stainless steel fine screen.
The unwanted solids accumulate on the inner surface of the fine screen, building up a filtercake, which filters out even finer particles, creating a pressure differential. Once the pressuredrop reaches a preset level, a rinse cycle is activated by the factory supplied control system.
The solids are removed from the fine screen using a spot backwashing method, whichaggressively sucks the dirt off the screen, similar to a vacuum cleaner, and are carried tothe drain via the rinse valve. The dirt collector rotates, ensuring the entire screen is cleanedeach cycle. The process takes a matter of seconds, without interruption of system flow.

Control Method
Filter has differential switch and integrator. Once the pressure drop reaches a preset level, a rinse cycle is activated by the PLC controller.

Feature
structure compact
low water consumption
fine filter degree
low pressure drop

Application 

1,Chilling water treating: such like cooling tower, water supplement system, air conditioning system, heat exchange system. 
2,Raw water treating: such like surface water, lake, sea water, tank water, well to remove grind, sand, algae, organism etc.
3,cycling industry water: cooling tower, polishing process water, ion exchange water, spraying process water, heat exchange plant, rolling plant, casting plant etc. 
4,irrigation: farm, dip field, golf, lawn etc. 
5,recycle water

Model Pipe T/HFilter 
area(cm2)
Drain(mm)Water
consumption (L)
motor(KW)weight(KG)
XLQ-200XT2003007500502500.55340
XLQ-250XT25045011000804000.55350
XLQ-300XT30065011000804000.55365
XLQ-350XT35090013800804000.55630
XLQ-400XT400120013800804000.55650
XLQ-350XT350150013800804000.55690


Install notice 

1.One check valve must be installed at filter outlet. Return pressure and back water is forbidden, in case of screen out of shape.
2.If system wok pressure over 0.8MPa, should install break valve at drain pipe to reduce impact to screen.
3.Notice motor rotating direction. Shut off power immediately once back rotating (anti-clock wise ) occurs. )
4.Installation each part according to arrow direction. 
5.Sudden pressure relief at outlet pipe is forbidden. Take normal work pressure 1.3MPa for example, if suddenly open branch valve at outlet, it will occur instant huge different pressure, which damage screen.
6.Make sure filter used under correct work pressure, capacity. 
7.If alarms, open by-pass valve for temporary back washing solutions. 
8.Make sure control box have constant power supply. If power off, users can open by-pass valve, close in and outlet valve and control box switch.


Install requirement 

1,Keep space for filter install and maintenance.
2,Drainage pipe length not longer than 20m. Avoid more turns off, keep outlet pipe parallel with ground. 
 
Testing 

1,Close inlet outlet valve before testing. Open by-pass valve. Wash dirties staying in pipes. 
2,Open inlet valve gradually. Let water into filter till air comes out from filter house. 
3,Check leak at joint part, check in/outlet pressure gauge. Connect power when comes to system pressure. 
4,Set up drainage time based on system pressure data. 
5,Open outlet valve gradually if testing is normal. Close by-pass valve back to normal filtering. 
6,Observe several differential pressure changes and drainage. Finish testing if normal.

                             Welcome to Inquire, We Will Offer You The Best Items ! 


Send your message to this supplier
Mrs. Yang

Post a Sourcing Request Now

People who liked this also liked
Get Quick Quotes