Gold Member Since 2011
Audited Supplier
Peide Water Treatment Equipment Co., Ltd.

Flange UV Sterilizer, Aquarium UV Sterilizer, UV Sterilizer Lamp manufacturer / supplier in China, offering Ultraviolet Light Disinfection UV Sterilizer for Industrial Water Purification, 120W-600W Water Treatment Machine for Cooling Recyclable Water, Recycling Water Treatment Equipment for Boiler Water Treatment System and so on.

(/ )

Supplier Homepage Product UV sterilizer Others UV sterilizer Ultraviolet Light Disinfection UV Sterilizer for Industrial Water Purification

Ultraviolet Light Disinfection UV Sterilizer for Industrial Water Purification

FOB Price: US $470-5,000 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $470-5,000/ Piece
Get Latest Price
Production Capacity: 3, 000 PCS/Year.
Transport Package: Woodencase
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: PDCn
  • Application: Industry
  • Disinfection Method: Ultrasonic
  • Water Flow: 1-300 M3/H
  • UV Lamp Brand: " Lightsource" From USA
  • Lamp Useful Life: 9000 Hour
  • Trademark: PEIDE
  • Origin: China
  • Certification: CE
  • Voltage: 220V
  • Material: Ss304,316L Plastic
  • UV Wavelength: 253.7nm
  • Single UV Lamp: 40W in General. We Can Aslo Supply 75W, 85W, 155
  • Condition: New
  • Specification: ISO9001: 2008
  • HS Code: 8543709990
Product Description
Ultraviolet Light Disinfection UV Sterilizer for Industrial Water Purification


1. FEATURES OF UV STERILIZER

1. Chemical free water treatment
2. Quality UV Lamps Manufacutred in the U. S. Are rated for 9000 hours
3. Sterilizers feature a built-in alarm. If the UV lamp fails, the alarm will sound.
4. Disinfect water of viruses and microbes
5. Great quality at lowest prices!
6. High flow rate. Low Pressure Drop
7. Heavy-duty stainless steel construction
8. High Bactericidal Efficiency
9. Safe and Reliable Operation
10. Large Amount of Water Disinfection, Wide Application

2. APPLICATIONS

1. Water reuse disinfection
1. Community secondary water disinfection
2. After municipal wastewater treatment disinfection
3. Aquaculture process water disinfection
4. Shellfish purification of water disinfection
5. Aquarium, tank, plant water disinfection of tap water, purified water, mineral water
6. Food and beverage industry water disinfection, water recreation facilities(swimming pool ect. )
7. Family, residential, office, hotel and other building
8.253.7nm uv intensity drinking water disinfection, pharmaceutical, cosmetics manufacturing sterile
9. Municipal landscape, hospital, Military bases, ships, submarines, outdoor activities water disinfection
10. Central air conditioning, cooling water, Various power plant, Commercial aircraft, large aircraft drinking water,
11. Agricultural irrigation, large poultry, livestock, Semiconductor and electronic industries, ultra-pure water disinfection.
12. Point-of-use; Post mix; Vending machines; Pharmaceuticals; Cooling towers; Boats and RVs; Pre- and post-reverse osmosis;
Fish hatcheries; Aquiculture; Bottled water; Cabins; Laboratories; Hospitals; Spas; Boiler feed water; Water softeners; And others.


3. Principle of Operation

UV water disinfection system design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber. The dosage, as it applies to UV disinfection, is a function of time and the intensity of UV radiation to which the water is exposed. Exposure time is related to the flow rate, the higher the flow rate, the lower the exposure time or the lower the flow rate, the higher the exposure time. The UV intensity is the amount of energy, per unit time, emitted by germicidal lamp. The Dosage is the product of UV intensity and the exposure time.

4...Limitation of Use

The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.

5. Water Quality (in)

Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels

Maximum Concentration Levels (Very Important)
Iron: ≤ 0.3ppm(0.3mg/L)
Hardness: ≤ 7gpg(120mg/L)
Turbidity: ≤ 1NTU
Manganese: ≤ 0.05ppm(0.05mg/L)
Tannins: ≤ 0.1ppm(0.3mg/L)
UV Transmittance: ≥ 750‰

Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.


Model NoFlow RateAll Lamps PowerIn / Outlet inchChamber dimensions

(m3/h)Wmminchesmm
PDCn-050240251"1000× Φ 89
PDCn-150680321-1/41000× 300× Φ 108
PDCn-2008120401-1/21000× 400× Φ 159
PDCn-30012160502"1000× 400× Φ 159
PDC-36015200652-1/2"1000× 400× Φ 159
PDC-50020240652-1/2"1000× 500× Φ 219
PDC-60025280803"1000× 500× Φ 219
PDC-700303201004"1000× 500× Φ 219
PDC-1000403601004"1000× 500× Φ 219
PDC-1300504251255"1000× 570× Φ 273
PDC-1500606201506"1700× 570× Φ 273
PDC-2000807751506"1700× 570× Φ 273
PDC-25001009301506"1700× 570× Φ 273
PDC-300012510851506"1700× 570× Φ 273
PDC-400015012402008"1700× 570× Φ 325


                    WELCOME TO INQUIRE, WE WILL OFFER YOU THE BEST ITEMS !
Send your message to this supplier
Avatar
Ms. Yang
*From:
To: Ms. Yang
*Message:

Enter between 20 to 4,000 characters.