Gold Member Since 2011
Audited Supplier
Peide Water Treatment Equipment Co., Ltd.

Self Cleaning Filter, Sucking Type Self Cleaning Filter, Swimming Pool Self Cleaning Filter manufacturer / supplier in China, offering Automatic Self-Cleaning Brush Type Water Filter for Water Treatment, Strong Magnetic Water Treatment System Water Processor, Aquaculture UV Sterilizer for Water Disinfection (CE, SGS certificates) and so on.

(/ )

Supplier Homepage Product Filter Series water filter for cooling water Automatic Self-Cleaning Brush Type Water Filter for Water Treatment

Automatic Self-Cleaning Brush Type Water Filter for Water Treatment

FOB Price: Get Latest Price
Min. Order: 1 Piece
Port: Shanghai, China
Production Capacity: 50000PCS/Year
Payment Terms: L/C, T/T, D/P, Western Union, Paypal

Request a custom order and have something just for you!

Send Customized Request
Product Catalog
self-cleaning filter,sand filter,bag filter housing,etc
24 Products
Content
Product Image
Product Name
FOB Price
Port
Basic Info
  • Usage: Water Treatment Water Filter
  • Style: Vertical
  • Certification: ISO
  • Filter Degree: 80-500 Microns
  • Connect Method: Flange
  • Voltage: 380V,50/60Hz
  • Trademark: PEIDE
  • Specification: Carbon Steel, 304ss, 316L
  • Motive Force: Electric power
  • Performance: Efficient Filtration
  • Installation: Vertical, Horizontal
  • Cleaning Method: Sucking Type
  • Control Panel: LCD
  • Control Type: Time,Pressure Differential,Manual Control
  • Transport Package: Wooden Cases
  • Origin: China
Product Description
Automatic Self-cleaning Brush Type Water Filter For Water Treatment

Automatic brush filter structure and working principle
Automatic brushaway filter is composed of the drive mechanism, the control circuit (including the pressure switch), filter components, cleaning device, connecting flanges and other major component parts.It cleans sewage by the drive motor and the electric valve automatically, the operation mode is automatic operation (option:manual operation), with timing control or pressure difference control. Its automated part is controlled by reliablePLC programmable controller.
Water enters into the filter, the mechanical impurities are intercepted.When the impurities accumulate for a period, reaches 0.05MPa, then the differential pressure switch will send signal, while the PLC command is issued, transmission motor starts, the drain valve opens, the impurities deposited on the filter is brushed away,and drain out.The whole process is without personnel, without downtime. Besides, the device also has the function of timing and manual cleaning to ensure that the outlet water is safe under any circumstances.
Automatic brush filter Two types of cleaning method
Automatic control: there are two types:timing control and pressure difference. Set the filtration time on the filter timer, when it reaches the setting time, the brush will start cleaning sewage,discharge time is also set by timer; while the system pressure control system with real-time user-defined pressure compared when the system pressure reaches the set pressure difference, the filter will start cleaning sewage, sewage discharge time set by the timer.The whole system returns to its initial state, prepare for the next filtration step.
Manual control: Press the manual button on the control panel, filters will start cleaning.


Automatic brush filter Feature
1.Filter precision from 100um to 3500um,big filter area,high sewage carrying capacity,customized product.
2.Simple turn-of-a-handle cleaning of the filter screen,adjust the parameter of the automatic cleaning system.Automatic cleaning.
3.Has motor overload protection, which can effectively protect the motor.
4.Eliminates the need for turning off the water and extracting the filter screen for rinsing.No interruption of the process water flow during cleaning,Low pressure loss:less than 1%.
5.Easy to maintenance,installation and disassemble.
6.Flange connections to the user's pipeline, national standard flange, versatility.


Automatic brush filter Technical Parameters


1. Treatment effectiveness
Filter precision:100-3000um(or customized)
Filtration efficiency: 99%;
Initial pressure loss: ≤0.015Mpa.
 
2. Inlet Water Quality
Working pressure: 1.0 / 1.6 / 2.5Mpa;
System pressure: >0.25Mpa;
Working temperature: 1 ºC -90 ºC;
Working environment temperature: 1 ºC -50 ºC;
Relative Humidity: <95%.
 
3. Operating parameters
Mean time between failures:> 60,000 hours;
Design life: 20 years for shell; 8 years for electrical parts.
Power: 0.2-0.6kw
Operating voltage: 220V ~ 380V ± 10%, 3-phase, 50 / 60Hz;
Safety insulation voltage: 5000V.   
 

4. Mesh to micron conversion chart

Micron(um)10012015020040080015003000
mesh150120100804020105


Automatic brush filter-"Y" type parameters

Automatic Self-Cleaning Brush Type Water Filter for Water Treatment
 
Model Inlet&outletMax flow rateDimension  DrainMotor
mmT/HLφL1mmKw/r/min
SLQ-2Y5019600159300250.18/1400
SLQ-3Y8050600159300250.18/1400
SLQ-4Y10080700159300400.18/1400
SLQ-5Y125125750219350400.18/1400
SLQ6Y150180800275450500.18/1400
SLQ-8Y200320850325525500.18/1400
SLQ-10Y250490900377650500.18/1400
SLQ-12Y300710950426700650.18/1400
SLQ-14Y3509701170478820650.18/1400

Automatic brush filter-"F" type parametersAutomatic Self-Cleaning Brush Type Water Filter for Water Treatment
Model Inlet&outletMax flow rateDimension  DrainMotor
mmT/HLφL1mmKw/r/min
SLQ-2F5019300159225250.18/1400
SLQ-3F8050300159270250.18/1400
SLQ-4F10080300159300400.18/1400
SLQ-5L125125350219365400.18/1400
SLQ6F150180600273450500.18/1400
SLQ-8F200320700325560500.18/1400
SLQ-10F250490700377700500.18/1400
SLQ-12F3007101000426800650.18/1400
SLQ-14F3509701000478940650.18/1400


Automatic brush filter-"L" type parameters
Automatic Self-Cleaning Brush Type Water Filter for Water Treatment

 
Model Inlet&outletMax flow rateDimension  DrainMotor
mmT/HLφL1mmKw/r/min
SLQ-2L5019300159250250.18/1400
SLQ-3L8050300159250250.18/1400
SLQ-4L10080300159250400.18/1400
SLQ-5L125125350219275400.18/1400
SLQ6L150180450273325500.18/1400
SLQ-8L200320525325360500.18/1400
SLQ-10L250490650377425500.18/1400
SLQ-12L300710700426450650.18/1400
SLQ-14L350970820478520650.18/1400

  The video of working principle:https://www.youtube.com/watch?v=ZgNtreTv8jc


Automatic brush filter internal fitting
Automatic Self-Cleaning Brush Type Water Filter for Water Treatment

Automatic brush filter installation chart

Automatic Self-Cleaning Brush Type Water Filter for Water Treatment
 
Automatic brush filter Installation Points for attention

1.The check valve must be installed to avoid back pressure or backwater phenomenon, caused by inward deformation of filter screen.
2.For the operating pressure above 0.8MPa or more, the gate valve must be installed on the sewage lines, it will reduce the pressure loss, and the impact after the drainage.(you may ask for specific advisory from suppliers)
3.Prohibit the sudden pressure relief. For example, the normal working pressure is 1.3MPa, shut down suddenly,and open the outlet piping manifold pressure relief valve, it will have a huge opening moments of pressure will cause filter damage.
4. Make sure that the filter works within the normal operating range, banned from overpressure, over flow rate. 
5.When the equipment alarms, if you can not handle at once, you should immediately open the bypass valve. Otherwise, thefilter can not hold pressure,andit also affectproduction.
6.For the filter with control box, you must ensure the continuous power supply for control box . Otherwise, it will cause filter clogging, the system hold pressure, impact production, and even cause filter damage. Re-transmission may occur because of filter clogging motor tripping the alarm. Power interruption is recommended to open the bypass valve, close the filter inlet and outlet valves and control box power switch. Filter restart when power on.
                                         
How to install Automatic brush filter


1. Equipment can not be installed in the negative pressure zone.
2. Noted the direction of the water flow.
3. By-pass conduit is preferably provided so that the normal operation of the filter for cleaning or failure does not affect the system;
4. Pipeline should be floated over 5m,supported by steel or concrete barrier.
5. When the filter installed with other water processor equipment,this filter should be installed before the inlet.



How to choose the suitable model
Please clarify below parameter:
1.Water flow rate
2.Chemical characteristic of fluid
3.SS of fluid
4.Filter precision
5.Pipe pressure
6.Working pressure
7.Direction of flow
8.Drainage way


Automatic Brush Filter Maintenance
1.After install the brushaway filter, the pipeline should be cleaned by banging pipes,to remove the welding slag and other debris,to preventdamage caused by slag debris.Wash the filter after initial running for a week.
2.Runtime system for the first time, you should first open the supply valve, until the system is filled with water, and then open the valve, in order to facilitate the removal of impurities in the pipeline, to prevent access to the coil;
3.Timely sewage drain (especially in summer) according to the system set pressure and concentration ratio.
4.In the dry state,it's prohibit to open device for a long time.During downtime or seasonal shutdown, it should be wet protected,in avoid of pipeline corrosion.

Automatic Brush Filter spare parts

Automatic Self-Cleaning Brush Type Water Filter for Water Treatment






                                         

                                         









     

 
Send your message to this supplier
Avatar
Ms. Yang
*From:
To: Ms. Yang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now