Gold Member Since 2011
Audited Supplier
Peide Water Treatment Equipment Co., Ltd.

Water Filter, Water Treatment, Water Filtration manufacturer / supplier in China, offering 1000m3/H Water Treatment Self Cleaning Irrigation Water Filtration Equipment, High Flow Stainless Steel Bag Filter Housing for Textile Printing Industry, Automatic Self Cleaning Filter for Irrigation Water (ISO9001, SGS Certificates) and so on.

(/ )

Supplier Homepage Product Self-cleaning filter Applied for Agricultural irrigation 1000m3/H Water Treatment Self Cleaning Irrigation Water Filtration Equipment

1000m3/H Water Treatment Self Cleaning Irrigation Water Filtration Equipment

FOB Price: US $470-500 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $470-500/ Piece
Get Latest Price
Port: Shanghai, China
Production Capacity: 1, 000PCS/Year
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: XLQ
  • Salt Rejection Rate: 98.5%
  • Capacity: 100 Gallon
  • Style: Vertical
  • Type: Water Filter
  • Water Flow: 19-1260 M3/H
  • Voltage: 380V, 50/60Hz
  • Trademark: PEIDE
  • Specification: ISO9001: 2008
  • HS Code: 8421299090
  • Certification: ISO9001, CE, SGS, ISO
  • Application: Industry
  • Performance: Efficient Filtration
  • Motive Force: Electric Power
  • Usage: Water Filter
  • Material: 304ss or 316L
  • Power: 0.37kw
  • Transport Package: Woodencase
  • Origin: China
Product Description
How It Works
 
The unit consists of two stages of filtration, a coarse pre-filter and a stainless steel fine screen.
  The unwanted solids accumulate on the inner surface of the fine screen, building up a filter cake, which filters out even finer particles, creating a pressure differential. Once the pressure drop reaches a preset level, a rinse cycle is activated by the factory supplied control system.
  The solids are removed from the fine screen using a spot backwashing method, which aggressively sucks the dirt off the screen, similar to a vacuum cleaner, and are carried to the drain via the rinse valve. The dirt collector rotates, ensuring the entire screen is cleaned each cycle. The process takes a matter of seconds, without interruption of system flow.

Control method

Filter has differential switch and integrator. Once the pressure drop reaches a preset level, a rinse cycle is activated by the PLC controller. 

Feature
Structure compact
Low water consumption
Fine filter degree
Low pressure drop

Application
1.Chilling water treating: such like cooling tower, water supplement system, air conditioning system, heat exchange system. 
2.Raw water treating: such like surface water, lake, sea water, tank water, well to remove grind, sand, algae, organism etc.
3.Cycling industry water: cooling tower, polishing process water, ion exchange water, spraying process water, heat exchange plant, rolling plant, casting plant etc.
4.Irrigation: farm, dip field, golf, lawn etc. 
5.Recycle water.

Filter degree
Mic (um)10012015020040080015003000
Mesh150120100804020105

Horizontal type
ModelIn and out diameter
(mm)
Flow rate
(T/H)
Filter area
(cm2)
DrainWater consumption(L)Motor
(KW)
Weight
(KG)
XLQ-50XM5020150050mm750.5585
XLQ-80XM8050150050mm750.5587
XLQ-100XM10080300050mm1500.55210
XLQ-125XM125100300050mm1500.55212
XLQ-150XM150150700050mm1500.55212
XLQ-200XM200300700050mm1500.55220
XLQ-250XM2504501100080mm4000.55395
XLQ-300XM3006001100080mm4000.55405
XLQ-350XM3509001350080mm4000.55625
 
Install wayHorizontal
Unit capacity15-900T/H,Achieve parallel install to achieve big capacity
Min work pressure0.25Mpa
Max work pressure1.0Mpa,1.6Mpa
Filter precision100-3000um
Control wayDifferential pressure, time and manual
Max temperature65ºC (reach to 100ºC if required)
Back wash time50-90S
Rotating speed14-20rpm
Clean wayScanning type
Differential pressure in cleaning0.01-0.08Mpa
Back wash water consumptionApproximate 280-310L
VoltageAC220V 380V,50Hz,3PH,CONTROLLER: 220V
Motor power0.37Kw
MaterialCarbon steel with anti-corrosion painting
ScreenMulti stainless steel mesh + pvc structure
Drain valvecast iron with anti-corrosion painting
PLC controller

Install notice 

1.One check valve must be installed at filter outlet. Return pressure and back water is forbidden, in case of screen out of shape.
2.If system wok pressure over 0.8MPa, should install break valve at drain pipe to reduce impact to screen.
3.Notice motor rotating direction. Shut off power immediately once back rotating (anti-clock wise )occurs. )
4.Installation each part according to arrow direction.
5.Sudden pressure relief at outlet pipe is forbidden. Take normal work pressure 1.3MPa for example,if suddenly open branch valve at outlet, it will occur instant huge different pressure,which damage screen.
6.Make sure filter used under correct work pressure, capacity.
7.If alarms, open by-pass valve for temporary back washing solutions.
8.Make sure control box have constant power supply. If power off, users can open by-pass valve,close in and outlet valve and control box switch. 

Install requirement 

1.Keep space for filter install and maintenance.
2.Drainage pipe length not longer than 20m. Avoid more turns off, keep outlet pipe parallel with ground.
Testing 
1.Close inlet outlet valve before testing. Open by-pass valve. Wash dirties staying in pipes.
2.Open inlet valve gradually. Let water into filter till air comes out from filter house.
3.Check leak at joint part, check in/outlet pressure gauge. Connect power when comes to system pressure.
4.Set up drainage time based on system pressure data.
5.Open outlet valve gradually if testing is normal. Close by-pass valve back to normal filtering.
6.Observe several differential pressure changes and drainage. Finish testing if normal.

Notice in using

Equipment can through into operation directly, as already has trial testing. Users can adjust settings based on actual use. Change relay's program and parameter is forbidden.
1st operation notice
Follow below steps in 1st operation
Check drainage pipe connection. No up-inclined angle.
Check connection tighten or not.
Check control box in a dry environment.
Connect power cord, green light means normal. Make sure electrical parts is dry.
Water is forbidden into control box.

Welcome to inquiry , we will offer you the best items !
Send your message to this supplier
Avatar
Ms. Yang
*From:
To: Ms. Yang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now