Gold Member Since 2011
Audited Supplier
Peide Water Treatment Equipment Co., Ltd.

Water Treatment, Water Treatment Plant, Water Descaler manufacturer / supplier in China, offering Remove Water Scale Descaling Electronic Water Descaler Water Softener, Clean Scale Magnetic Water Treatment for Pipes Water Treatment, Best Water Softener (ISO9001: 2008 SGS Certifications) and so on.

(/ )

Supplier Homepage Product Descaling Equipment Others Descaling Equipment Remove Water Scale Descaling Electronic Water Descaler Water Softener

Remove Water Scale Descaling Electronic Water Descaler Water Softener

FOB Price: US $480-500 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $480-500/ Piece
Get Latest Price
Production Capacity: 2, 000PCS/Year
Transport Package: Woodencase
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: CLDC-2.5CR
  • Application: Water Descaling
  • Pipeline Diameter: Od15mm To1500mm
  • Specification: ISO9001: 2008
  • HS Code: 8421299090
  • Voltage: 220VAC 50Hz
  • Power: 2.5-42W
  • Trademark: PEIDE
  • Origin: China
Product Description


Working principle
Scale Form Principle: When the mineral content exceed the saturation solubility, calcium, magnesium and carbonate ion will precipitate and form the Calcite which adheres to the surface of pipe. What's more, the scale will disassemble to ion. When the rate of precipitation is higher than the rate of disassemble, the depth of scale will increase.

Prevent Scale: 
Electronic Induction water treatment equipment will form the electromagnetic field which has regular changing in frequency and intensity. The electromagnetic field makes the carbonate ion forming quantity Aragonite. When mineral content exceed the saturation solubility, carbonate ion will form the Aragonite preferential. The tendency of forming Calcite will reduce. The adhesion of Aragonite is weak and Aragonite is soft, flocculent and suspend on the water. It is easy to remove by water flow to reaches to the purpose of preventing scale.

Cleaning Scale:
 The scale which is on the surface of pipe disassembles to carbonate ion. The carbonate will form the Aragonite instead of Calcite in AV function. What's more, the scale will be off from the surface of pipe.

Activation: 
The electromagnetic field will damage hydrogen bond so as to destroy the macromolecular group to small molecular group. Then the tension of water surface will reduce, water activation will increase, solubility improve, penetration strengthen.

Kill bacterial: 
Scale is breeding ground of bacterial. If the scale is cleaned. That's means, the breeding ground of bacterial is cleaned. What's more, the electromagnetic field will damage the cell's cytoderm to cause difficult to survive. The solubility ability and dissolve of oxygen will improve in water after treated to inhibit anaerobic bacterial survive.

Descaling and prevent corrosion: 
Water rust will be cleaned in electromagnetic field. It will produce the Metal oxide film which can inhibit the water rust producing.

Work principle
Remove Water Scale Descaling Electronic Water Descaler Water Softener

Characteristic
1. Prevent scale, Clean scale
2. It need not to cut the pipe just need to wound the line on the surface of pipe
3. It's applied to metal pipe and non-metal pipe
4. Low cost, low electricity consumption, No maintain
5. No need chemical to treat water
6. Ameliorate heat exchange rate, save energy about 30-50%.
7. Appropriate pipe diameter: 15-1500mm
8. Life: 20years

Comparison with Other Scale Treating Equipment
 Type Water condition Influence to equipment results Lifetime
 Ion exchange Has pollution rust equipment only remove scale several years
 Chemical dosing Has pollution rust equipment remove scale, bacterial, algae --
 Chemical cleaning Severe pollution strongly rust equipment only remove scale --
 Statistic electricity No pollution rust equipment not good result 10 years
 Ion stick No pollution rust equipment remove bacterial algae, not good at remove scale 3-5 years
 Electric magnetic No Pollution rust equipment remove scale, bacterial, algae 15 years

Application:
Industry
oil field, oil-gather station, boiler, water-supply system
Color metallurgical, steel mill cooling system, heat exchange system, electricity cooling system.
Beer factory, beverage bottle clean plant.
Paper mill: evaporator, heat exchange
Vacuum boiler, vacuum pump
 
Commercial
Domestic boiler,wall-hanging boiler
Central air conditioning system: cooling recycling water
Swim pool heat-supply system, filtering and sterilizer equipment.
Irrigation
Pipe heat exchange system
Hot spring, ground water system
Punching and welding factory


Remove Water Scale Descaling Electronic Water Descaler Water Softener

Main parameters include:
Material: Metal Shell (Main board)
Power input: 20VAC   50HZ
Ambient limitation:  -10...+60°C
Ambient relative humidity: ≤80%
Pipe External temperature: common cable wire <70ºC
high-temperature allowance cable: <130ºC
Pipeline diameter: OD15mm to1500mm

 

 Water descaler Specification
 ModelPipe diameter Power (W) Input Voltage
 CLDC-2.5CR 65 2.5 220VAC 50 HZ
 CLDC-3CR 80 2.5
 CLDC-4CR 100 3.0
 CLDC-5CR 125 3.5
 CLDC-6CR 150 5.0
 CLDC-8CR 200 13
 CLDC-10CR 250 18
 CLDC-12CR 300 26
 CLDC-14CR 350 28
 CLDC-16CR 400 33
 CLDC-18CR 450 38
 CLDC-20CR 500 42

 

Advantages
1,increase work efficiency
Increase heat exchange rate, good for keeping a stable process. It shows excellent benefits especially in chemical companies.
save energy
 
It reduces pump energy consumption, as thick water scale increase flow resistance. It also helps improve heat conductivity factor, increase heat using rate. Take 350MW electricity plant units as example. It requires coal consumption exceed 1.2T/H, whole year cost 0.6M$. Electrical induction descaler helps solve problems, avoid scale forming, which equals to save 0.6M$ per year.
 
2,save water resource
Electrical induction descaler bear much higher water hardness, concentration value reach to 4-6, compare with traditional treating ways.
Take chemical fertilizer company as example. Pipe diameter is 1100mm, recycling evaporation is 36 m3/h. Increase concentration value from 1.7 to 4.0, see below grid on water consumption:
 Concentration value  N=1.7  N=4
  Water supply(m3/h)  80  44
  Drain+wind loss(m3/h)  47 11

If operation 8000hours per year, save water (80-44)c/h×8000h=28.8m3/year.
Save water cost 120K$.
 
3,save chemical dose
Tradition way is to add chemical dose, Take coal-chemical company as example. Pipe diameter 800mm: water supply 60m3/h, concentration value 2.5, solution concentration 50mg/L, chemical cost: 2000$/ton, effective ingredients 50%.If operate 8000hours a year, chemical dosage:60m3/h×8000h×50mg/L÷50%÷2.5=19.2ton, save USD38,350 per year.
 
4,protect equipment
Electrical induction descaler helps equipment avoid corrosion in structure, extend lifetime 30%.
 
5,reduce incident
Electrical induction descaler has small size. No need cut pipeline, safe operation, weak electricity and magnetism, not harmful to human and equipment. It keep equipment away from corrosion failure.

Remove Water Scale Descaling Electronic Water Descaler Water Softener
 

FAQ 

 

Do you have certificates?

Yes , we have ISO certificate and certificate of patent

Do you have design team?

We have a professional design team provide drawings, we wait for your confirmation and production

Can you guarantee delivery time ?

Timely transport, ensure the delivery time

Are you maufacturer ?

Yes, we are the professional water treatment equipment manufacturer in china 
           

  WELCOME TO INQUIRE, WE WILL OFFER YOU THE BEST ITEMS !

 
Send your message to this supplier
Avatar
Ms. Yang
*From:
To: Ms. Yang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now