Gold Member Since 2011
Audited Supplier
Peide Water Treatment Equipment Co., Ltd.

Water Filter, Water Treatment, Backwash Water Filter manufacturer / supplier in China, offering Automatic Backwash Water Filter for Groundwater Water Treatment, 100um Carbon Steel 220V50Hz Automatic Brushaway Water Filter, Hot Sale 230V50Hz Industrial Brushaway Water Filter Machine and so on.

(/ )

Supplier Homepage Product Filter Series Others Filter Series Automatic Backwash Water Filter for Groundwater Water Treatment

Automatic Backwash Water Filter for Groundwater Water Treatment

FOB Price: US $470-500 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $470-500/ Piece
Get Latest Price
Production Capacity: 2, 000PCS/Year
Transport Package: Woodencase
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: FLQ-PZ
  • Usage: Environmental Protection, Chemical Industry
  • Style: Vertical
  • Certification: SGS, ISO
  • Application: Water Filter
  • Single Flow Rate: 20-1000m3/H(88-4400gpm)
  • Cleaning Method: Brushwash
  • Working Pressure: 0.6 MPa,1.0 MPa,1.6 MPa,2.5 MPa
  • Seal Ring: O-Ring or Washer
  • Specification: ISO9001: 2008
  • HS Code: 8421299090
  • Type: Water Filter
  • Motive Force: Electric power
  • Performance: Efficient Filtration
  • Chamber Material: Carbon Steel,304ss or 316L
  • Certificates: ISO9000,SGS
  • Filtration Precision: 1000-5000micron
  • Control Type: PLC
  • Drain Valve: Automatic Drain Valve
  • Trademark: PEIDE
  • Origin: China
Product Description

Automatic Backwash Water Filter for Groundwater Water Treatment 

Structure and Working Principle

P-type automatic sewage filter is made of high-quality carbon steel cylinder, the special structure of the stainless steel wedge filter screen, flow direction valve and sewage drain. In the working status, flow direction valve is on, the water flow from the inlet into the filter, through the filter screen to the outlet (see Figure 1). When the filter needs sewage, flow direction valve closed, open the drain valve, water flows through the first half of the mesh filter, part of the water flow into the system from the outlet, the remaining water flow from the backside of the filter into the inside, automatic backwash the filter screen (see Figure 2). So that the entire washing process is operating normally, without downtime. Flow direction valve opening mechanism include sub-manual and electric type, when using an electric opening mechanism with clock control electrical control box, it can set the time required to achieve automatic cleaning sewage, then the outfall installed electric ball valves, flow direction valve and sewage electric valve to achieve linkage.
Automatic Backwash Water Filter for Groundwater Water Treatment

 

 

 

Features:
 

1.Small volume, low cost, no filter, a small amount of maintenance. Long mesh tube network life and high reliability.

2.High degree of automation, easy operation and management, long-term unattended operation.

3. Low pressure loss, energy saving, the use of the main channel hydraulic backwash, no need for backwash water.

4. Filtration precision: 1000-5000μm.

5. Easy to install, can be installed directly on the pipe, particularly suitable for field use under various process conditions.

6. Widely usage, ensure a safe operation of the water utility, simple and reliable method in any backwash process, can maintain uninterrupted normal operation.

 

Applications:
 

1. The domestic water supply, water supply and pre-filtering for industrial water supply;

2. steel, petroleum, chemical, paper, automotive, food, metallurgy and other industries beginning circulating water filtration;

3. Fist stage of circulating cooling water filtration;

4. The water reuse, waste water treatment filter;

5. Central air conditioning, boiler return early filter;

6. Municipal, green spraying, irrigation, agricultural irrigation, drip irrigation water filter early.



P-type backwash filter installation diagram

Model
Inlet&outlet
A
L
d
Flow rate
inch
mm
mm
mm
mm
T/H
FLQ-2P
2
50
410
340
25
19
FLQ-3P
3
80
500
400
25
50
FLQ-4P
4
100
580
470
40
80
FLQ-5P
5
125
640
530
40
125
FLQ-6P
6
150
730
610
50
180
FLQ-8P
8
200
900
750
50
320
FLQ-10P
10
250
1059
900
50
490
FLQ12P
12
300
1300
1100
65
710
FLQ-14P
14
350
1450
1250
65
970
FLQ-16P
16
400
1600
1350
65
1260
FLQ-18P
18
450
1800
1500
100
1590


Parameter

Single flow rate
20-1000m3/h(88-4400GPM)
The least working pressure
≤2.5bar
The highest working pressure
≤10bar
The pressure loss of cleaning
≤0.15bar
The highest temperature of working
≤150ºC=302°F
The water consumption of self-cleaning one time
1%-2% of all water flow
Filter precision
≥1.2mm
Cleaning method
Brushwash
Cleaning Time
30-90 seconds
Connect Method
flange
Drain Diameter
25-100mm
Installation lamp
Have
Chamber treated method
Coslettizing
Working pressure
0.6 MPa,1.0 MPa,1.6 MPa,2.5 MPa
Filter precision
0.8-5mm(or customized)

 

Electric

Voltage
220V,50Hz
Power
100W
Control panel chamber material
Carbon steel,304ss or 316L
Control type
PLC

 

Equipment material

Chamber material
Carbon steel,304SS or 316L
Strainer material
304SS or 316L
Strainer type
Stainless steel complex strainer
Cleaning system
Butterfly valve
Drain valve
Automatic drain valve
Seal ring
O-ring or washer

 

 
Automatic Backwash Water Filter for Groundwater Water Treatment


 Installation Precautions
 

1. The principle of selection:according to the pipe diameter, the premise of meeting the working pressure and flow, try to use a larger standard models.

2. backwash filter mounted on the front of various types of valve inlet pipe configuration. Install a shut-off valve in front of the filter,Install a drain valve at the bottom of the filter, horizontal mounting the equipment, pay attention to the direction of the arrow marked on the equipment, make sure it is consistent with the medium flow direction direction; if mounted vertically, should make the inlet up, the water flowing into the apparatus from top to bottom.

3. Install three days after the first wash, after wash once a month, according to the water quality after proper cleaning.

4.Installed in the negative zone.

5. filters and water treatment equipment for use, should be installed before the intake of water treatment equipment.

6. bypass can be installed in order to facilitate maintenance.

 


FAQ

 

Do you have certificates?

Yes , we have ISO / CE certificate and certificate of patent

 

Do you have design team?

We have a professional design team provide drawings, we wait for your confirmation and production

 

Can you guarantee delivery time ?

Timely transport, ensure the delivery time

 

Are you maufacturer ?

Yes, we are the professional water treatment equipment manufacturer in china

                     

                  Welcome To Inquire, We Will Offer You The Best Items !

Send your message to this supplier
Avatar
Ms. Yang
*From:
To: Ms. Yang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now